• Image
  • Image
  • Image

IBC SFC Superflow

A dual fired combi the SFC provides not only high-efficiency space heating, but unrivaled domestic hot water efficiency too. We call this ‘Double HE’. The secret lies in our patented two-in-one heat exchanger that ensures optimal heat transfer and minimal heat loss. Flue gases are condensed with both space heating and domestic hot water production ensuring heat extraction to the fullest extent possible. The IBC SFC boiler assures you unrivaled high-efficiency and economical operation year in, year out.

  • Specifications
    • Available in 3 models, 99K BTH, 125K BTH, and 199k BTH
    • Unit has 5 moving parts
    • Reduced induced internal parts for ease of installation
    • New illuminated touch screen for easy setup.
    • 30-year track record, 2 million installations worldwide
    • Will accept a 0-10 VDC signal
    • 95% AFUE with full ASME-rated heat exchanger
    • Packaged with a high-efficiency variable speed pump (ECM)
  • Where to buy

    Units are stocked locally. Complete in house design and technical support is available 8:00am to 5:00pm with on call tech support after hours. If you are looking for design help or an installer in your area contact us at 800-665-3336 x 206 or email us at info@edenenergy.com

  • Technical Specs

    Specifications SFC 199 SFC 125 SFC 99
    CSA Input (Natural Gas or Propane) – MBH 28.3 – 125 16.5 - 99 15.5 - 99
    CSA Output – MBH 27.1 - 111 15.8 - 88.9 14.8 - 88.9
    DHW – CSA Input (Natural Gas or Propane) – MBH 28.3 – 199 16.5 - 125 15.5 - 99
    A.F.U.E 95% 95% 96% ( EF .89% )
    Min gas pressure (Nat. Gas or Propane) – inch w.c. 4 4 4
    Max Gas Pressure (Nat. Gas or Propane) – inch w.c. 14
    Power (120Vac/60Hz) – Watts @ full fire with internal pump 120 120 120
    Pressure vessel water content – USG/Liters 0.19/.72 0.19/.72 0.19/.72
    Max boiler flow rate – USgpm 12 10 10
    Min boiler flow rate – USgpm 2 2 2
    Max operating pressure – Space Heating Coil – psig 43.5 43.5 43.5
    Max operating pressure – Domestic Hot Water Coil – psig 150 150 150
    Min water pressure – psig 8 8 8
    Min water temperature – Space Heating (°F/°C) 50/10 50/10 50/10
    Max water temperature – Space Heating (°F/°C) 194/90 194/90 194/90
    Min water temperature – Domestic Hot Water (°F/°C) 104/40 104/40 104/40
    Max water temperature – Domestic Hot Water (°F/°C) 149/65 149/65 149/65
    Min flow rate to activate DHW heating – USgpm 0.5 0.5 0.5
    Max flow rate DHW heating – USgpm 7 4 4
    Max equivalent vent length 2″ (each side) 35′ 35′ 35′
    Max equivalent vent length 3″ (each side) 120′ 120′ 120′
    Domestic hot water delivery:  @70°F/ 39°C temp. rise 5.0 GPM 3.2 GPM 2.4 GPM

    Questions? Call us at 800-665-3336 x 206 or email info@edenenergy.com

  • Connections & Measurements
  • Documentation
    Download Sales Brochure SFC Combi
    Engineering Submittal SFC Combi
    Install & Operation Manual SFC Combi
    Controller Manual SFC Combi

Design & Support Services

Eden Energy provides complete in-house design assistance for all of our products, including radiant infloor, geothermal, and air exchangers. Our technical team is available Monday to Friday 8:00 to 5:00pm with on call tech 7 days a week.

Industry Leading Training

Eden Energy has a training facility where we offer hands on training for all products, and a Technical Support team to help on the phone and in the field. We also provide online and remote training with industry recognized trainers.

About Us

Eden Energy Equipment Limited was established in 1981 as a wholesale /distribution company to service specialized markets in the HVAC industry.